Test results test_can_rxconv.RQ_TORQ_CRSH_GRB.ST_RQ_TORQ_GRB

Package: 20B6_0000208D_179_010_001 A_CAN
Test variant: A_CAN
Date: 01.10.2013

Variable check

Test NameDescriptionState
CAN signal'ST_RQ_TORQ_GRB' available in Inca.PASSED
ECU internal variable'Com_stTrqGbxDes_A' available in Inca.PASSED

Test preconditions

Resolution checkState
ECU internal resolution (Com_stTrqGbxDes_A=1) is equal or higher than bus resolution (ST_RQ_TORQ_GRB=1)PASSED

Physical unit checkState
No physical units givenINFO

Check signal conversion
FlexRay signal - bus name: ST_RQ_TORQ_GRB
FlexRay signal - Inca name: ST_RQ_TORQ_GRB
ECU internal variable - name: Com_stTrqGbxDes_A
Allowed absolute deviation (phys): 1

Bus SignalBus ValueECU VariableECU ValueDeviationState
ST_RQ_TORQ_GRB0Com_stTrqGbxDes_A00PASSED
ST_RQ_TORQ_GRB1Com_stTrqGbxDes_A10PASSED
ST_RQ_TORQ_GRB7Com_stTrqGbxDes_A70PASSED
ST_RQ_TORQ_GRB13Com_stTrqGbxDes_A130PASSED
ST_RQ_TORQ_GRB14Com_stTrqGbxDes_A140PASSED
ST_RQ_TORQ_GRB15Com_stTrqGbxDes_A150PASSED


Generated by loghtml.pm v1.1.0 on 01.10.2013 10:51:25